EVALUATION OF IMPLANTS USING THE ALL-ON-FOUR TECHNIQUE IN MANDIBLES THROUGH FINITE ELEMENT ANALYSIS: A LITERATURE REVIEW
DOI:
https://doi.org/10.24980/ucm.v16i19.6752Keywords:
All-on-Four, finite element analysis, dental implants, dental prosthesis, implant-supportedAbstract
With advances in titanium alloys, implant design, and particularly surface treatments, new rehabilitation options have been developed to reduce treatment time, morbidity, and costs while providing greater patient comfort. The All-on-Four technique is one such option and involves the placement of four implants to rehabilitate completely edentulous arches, including cases of bone atrophy, potentially reducing the need for extensive bone grafting procedures or more invasive surgeries. One of the main limitations of rehabilitation with osseointegrating implants is related to bone availability in the region posterior to the mental foramina in atrophic mandibles, which makes conventional implant placement difficult. As an alternative, the All-on-Four technique uses four implants in the mandible, with the posterior implants tilted distally to optimize the use of available bone tissue and reduce cantilever length. Different methodologies can be employed to study the configuration and mechanical resistance of implants and bone tissue, including photoelasticity, strain gauge analysis, and the finite element method. Among these methodologies, the finite element method stands out for enabling the individual assessment of structures and the analysis of interactions among tissue responses, implants, and the characteristics of prosthetic restorations. In this context, a literature review was conducted using the Google Scholar, BIREME, Dedalus, and LILACS databases, employing the search terms “All-on-Four,” “finite elements,” “dental implant,” and “implant-supported full-arch prosthesis,” and considering relevant publications from the past 25 years. The studies analyzed demonstrated that stress distribution in All-on-Four rehabilitations is primarily influenced by implant position and angulation, cantilever length, and the characteristics of the prosthetic configuration, highlighting the importance of individualized biomechanical planning.
References
AGLIARDI, E. et al. Immediate loading of full-arch fixed prostheses supported by axial and tilted implants for the treatment of edentulous atrophic mandibles. Quintessence International, Berlin, v. 41, n. 4, p. 285-293, Apr. 2010. Disponível em: https://pubmed.ncbi.nlm.nih.gov/20305862/.
ALMEIDA, E. O. et al. Tilted and short implants supporting fixed prosthesis in an atrophic maxilla: a 3D-FEA biomechanical evaluation. Clinical Implant Dentistry and Related Research, Hamilton, v. 17, supl. 1, p. e332-e342, Jan. 2015. Disponível em: https://doi.org/10.1111/cid.12129.
BAGGI, L. et al. The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: a three-dimensional finite element analysis. Journal of Prosthetic Dentistry, St. Louis, v. 100, n. 6, p. 422-431, Dec. 2008. Disponível em: https://doi.org/10.1016/S0022-3913(08)60259-0.
BAGGI, L. et al. Implant-bone load transfer mechanisms in complete-arch prostheses supported by four implants: a three-dimensional finite element approach. Journal of Prosthetic Dentistry, St. Louis, v. 109, n. 1, p. 9-21, Jan. 2013. Disponível em: https://doi.org/10.1016/S0022-3913(13)60004-9.
BARÃO, V. A. R. et al. Comparison of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible: a computed tomography-based three-dimensional finite element analysis. Journal of Biomechanics, Oxford, v. 46, n. 7, p. 1312-1320, Apr. 2013. Disponível em: https://doi.org/10.1016/j.jbiomech.2013.02.008.
BEVILACQUA, M. et al. The influence of cantilever length and implant inclination on stress distribution in maxillary implant-supported fixed dentures. Journal of Prosthetic Dentistry, St. Louis, v. 105, n. 1, p. 5-13, Jan. 2011. Disponível em: https://doi.org/10.1016/S0022-3913(10)60182-5.
BONNET, A. S.; POSTAIRE, M.; LIPINSKI, P. Biomechanical study of mandible bone supporting a four-implant retained bridge: finite element analysis of the influence of bone anisotropy and foodstuff position. Medical Engineering & Physics, London, v. 31, n. 7, p. 806-815, Sept. 2009. Disponível em: https://doi.org/10.1016/j.medengphy.2009.03.004.
BRÅNEMARK, P. I. et al. Osseointegrated implants in the treatment of the edentulous jaw: experience from a 10-year period. Scandinavian Journal of Plastic and Reconstructive Surgery Supplement, v. 16, p. 1-132, 1977. Disponível em: https://pubmed.ncbi.nlm.nih.gov/356184/.
BRÅNEMARK, P. I.; SVENSSON, B.; VAN STEENBERGHE, D. Ten-year survival rates of fixed prostheses on four or six implants ad modum Brånemark in full edentulism. Clinical Oral Implants Research, Copenhagen, v. 6, n. 4, p. 227-231, Dec. 1995. Disponível em: https://doi.org/10.1034/j.1600-0501.1995.060405.x.
BUTURA, C. C.; GALINDO, D. F.; JENSEN, O. T. Mandibular all-on-four therapy using angled implants: a three-year clinical study of 857 implants in 219 jaws. Dental Clinics of North America, v. 55, n. 4, p. 795-811, Oct. 2011. Disponível em: https://doi.org/10.1016/j.cden.2011.07.015.
CAPELLI, M. et al. Immediate rehabilitation of the completely edentulous jaw with fixed prostheses supported by either upright or tilted implants: a multicenter clinical study. International Journal of Oral & Maxillofacial Implants, Lombard, v. 22, n. 4, p. 639-644, July/Aug. 2007. Disponível em: https://pubmed.ncbi.nlm.nih.gov/17929526/.
FARIA ALMEIDA, D. A. de et al. Influence of tapered and external hexagon connections on bone stresses around tilted dental implants: three-dimensional finite element method with statistical analysis. Journal of Periodontology, v. 85, n. 2, p. 261-269, Feb. 2014. Disponível em: https://doi.org/10.1902/jop.2013.120713.
FAZI, G. et al. Three-dimensional finite element analysis of different implant configurations for a mandibular fixed prosthesis. International Journal of Oral & Maxillofacial Implants, Lombard, v. 26, n. 4, p. 752-759, July/Aug. 2011. Disponível em: https://pubmed.ncbi.nlm.nih.gov/21841984/.
FRANCETTI, L. et al. Bone level changes around axial and tilted implants in full-arch fixed immediate restorations: interim results of a prospective study. Clinical Implant Dentistry and Related Research, Hamilton, v. 14, n. 5, p. 646-654, Oct. 2012. Disponível em: https://doi.org/10.1111/j.1708-8208.2010.00304.x.
IKAR, M. et al. Mechanical stress during implant surgery and its effects on marginal bone: a literature review. Quintessence International, Berlin, v. 51, n. 2, p. 142-150, 2020. Disponível em: https://doi.org/10.3290/j.qi.a43664.
JENSEN, O. T. et al. The all on 4 shelf: mandible. Journal of Oral and Maxillofacial Surgery, Philadelphia, v. 69, n. 1, p. 175-181, Jan. 2011. Disponível em: https://doi.org/10.1016/j.joms.2010.06.207.
KIM, K. S. et al. Biomechanical comparison of axial and tilted implants for mandibular full-arch fixed prostheses. International Journal of Oral & Maxillofacial Implants, Lombard, v. 26, n. 5, p. 976-984, Sept./Oct. 2011. Disponível em: https://pubmed.ncbi.nlm.nih.gov/22010079/.
MALHOTRA, A. O. et al. Load transfer in tilted implants with varying cantilever lengths in an all-on-four situation. Australian dental journal. v. 57, n. 4, p. 440–445. Disponível em: https://doi.org/10.1111/adj.12002.
MALÓ, P.; RANGERT, B.; NOBRE, M. "All-on-Four" immediate-function concept with Brånemark System implants for completely edentulous mandibles: a retrospective clinical study. Clinical Implant Dentistry and Related Research, Hamilton, v. 5, supl. 1, p. 2-9, 2003. Disponível em: https://doi.org/10.1111/j.1708-8208.2003.tb00010.x.
MISCH, C. E. Prótese sobre implante. São Paulo: Santos, 2006.
NAINI, R. B. et al. Tilted or parallel implant placement in the completely edentulous mandible? A three-dimensional finite element analysis. International Journal of Oral & Maxillofacial Implants, Lombard, v. 26, n. 4, p. 776-781, July/Aug. 2011. Disponível em: https://pubmed.ncbi.nlm.nih.gov/21841987/.
SIRANDONI, D. et al. Effect of different framework materials in implant-supported fixed mandibular prostheses: a finite element analysis. International Journal of Oral & Maxillofacial Implants, Lombard, v. 34, n. 6, p. e107-e114, Nov./Dec. 2019. Disponível em: https://doi.org/10.11607/jomi.7255.
SRIREKHA, A.; BASHETTY, K. Infinite to finite: an overview of finite element analysis. Indian Journal of Dental Research, v. 21, n. 3, p. 425-432, July/Sept. 2010. Disponível em: https://doi.org/10.4103/0970-9290.70813.
TAKAHASHI, T.; SHIMAMURA, I.; SAKURAI, K. Influence of number and inclination angle of implants on stress distribution in mandibular cortical bone with All-on-4 Concept. Journal of Prosthodontic Research, v. 54, n. 4, p. 179-184, Oct. 2010. Disponível em: https://doi.org/10.1016/j.jpor.2010.04.004.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Eduardo Francisco de Souza FACO, Bianca Dal Oca Costa SILVA, Geovanna Carolina Elias SILVA, Gustavo Henrique Martins ROTULO, Giovana Caroline Ribeiro COSTA, Vinícius Franzão GANZAROLI, Flávia Priscila PEREIRA (Autor)